top of page

Vector Borne Disease

Multi-arbovirus

STANDARD Q Arbo Panel I (Z/D/C/Y)

STANDARD Q Arbo Panel I (Z/D/C/Y) test is an immunochromatographic assay for the detection of IgM to Zika or Dengue or Chikungunya or Yellow fever virus and Dengue NS1 antigen in human serum, plasma, or whole blood. Screening test results can be obtained within 15 minutes with high sensitivity and specificity.

  • Detect Zika/Dengue/Chikungunya/Yellow fever virus IgM and Dengue NS1 Ag simultaneously at once

  • Easy to use, Easy to read and interpret

  • Room temperature storage

STANDARD Q ZIKV/DENV/CHIKV/YFV IgM Quad

STANDARD Q ZIKV/DENV/CHIKV/YFV IgM Quad test is an immunochromatographic assay for the detection of IgM to Zika or Dengue or Chikungunya or Yellow fever virus in human serum, plasma, or whole blood. Screening test results can be obtained within 15 minutes with high sensitivity and specificity.

  • Detect Zika/Dengue/Chikungunya/Yellow fever virus IgM simultaneously at once

  • Easy to use, Easy to read and interpret

  • Room temperature storage

STANDARD Q ZIKV/DENV/CHIKV Fast Quad

STANDARD Q ZIKV/DENV/CHIKV Fast Quad test is an immunochromatographic assay for the detection of Dengue IgM or Dengue NS1 or Zika IgM or Chikungunya IgM in human serum, plasma, or whole blood. Screening test results can be obtained within 15 minutes with high sensitivity and specificity.

  • Detect Dengue IgM or Dengue NS1 or Zika IgM or Chikungunya IgM simultaneously at once

  • Easy to use, Easy to read and interpret

  • Room temperature storage

STANDARD Q Dengue/Chikungunya Trio

STANDARD Q Dengue/Chikungunya Trio test is an immunochromatographic assay for the detection of dengue IgM/IgG or Dengue NS1 or Chikungunya IgM/ IgG in human serum, plasma, or whole blood. Screening test results can be obtained within 15 minutes with high sensitivity and specificity.

  • Detect Dengue IgM/IgG or Dengue NS1 or Chikungunya IgM/IgG simultaneously at once

  • Easy to use, Easy to read and interpret

  • Room temperature storage

STANDARD Q Zika/Dengue Fast Trio

STANDARD Q Zika/Dengue Fast Trio test is an immunochromatographic assay for the detection of IgM antibodies specific for Dengue virus and NS1 antigen as well as Zika virus-specific IgM antibodies in human serum, plasma, and whole blood. Screening test results can be obtained within 15 minutes with high sensitivity and specificity.

  • Detect Zika and Dengue simultaneously at once

  • Easy to use, Easy to read and interpret

  • Room temperature storage

Zika

STANDARD F Zika Ag FIA

STANDARD F Zika Ag qualitatively analyzes Zika virus antigen in serum, plasma, and whole blood using fluorescent immunoassay. Screening test results can be obtained within 15 minutes with high sensitivity and specificity.

  • Able to perform qualitative analysis with high sensitivity and specificity by using a fluorescent substance

  • The objective result - Eliminates the subjectivity of a visual result

  • Automatic strip recognition by reading the information stored in the 2D barcode

  • Time-saving by early detection - in case of high titer samples, the analyzer automatically shows the test results in 5 minutes.

STANDARD F Zika IgM FIA

STANDARD F Zika IgM FIA qualitatively analyzes Zika virus specific IgM antibodies in serum, plasma, and whole blood using fluorescent immunoassay. Screening test results can be obtained within 15 minutes with high sensitivity and specificity.

  • Able to perform qualitative analysis with high sensitivity and specificity by using fluorescent substance

  • Objective result - Eliminates the subjectivity of a visual result

  • Automatic strip recognition by reading the information stored in the 2D barcode

STANDARD Q Zika IgM

STANDARD Q Zika IgM qualitatively analyzes IgM antibodies specific to Zika virus in serum, plasma, and whole blood using immunochromatography. Screening test results can be obtained within 15 minutes with high sensitivity and specificity.

  • Differential detection of IgM antibodies

  • Easy to use, easy to read and interpret

  • Room temperature storage

  • Able to read positive/negative infections fast and accurately with a little amount of sample (10 µl)

STANDARD Q Dengue NS1 Ag

STANDARD Q Dengue NS 1 Ag qualitatively analyzes NS1 antigens specific to Dengu virus in serum, plasma and whole blood using immunochromatography. By detecting Dengue NS1 antigens, the initial infection status of the Dengue virus can be discriminated, and the screening test result can be obtained within 15 minutes with its high sensitivity and specificity.

  • Easy to use, easy to read and interpret

  • Room temperature storage

  • Performance
    Sensitivity : 92.9% (184/198) / Specificity : 98.7% (222/225)

Dengue

STANDARD F Dengue NS1 Ag

STANDARD F Dengue NS1 Ag qualitatively analyzes Zika virus NS1 antigen in serum, plasma and whole blood using fluorescent immunoassay. Screening test results can be obtained within 15 minutes with high sensitivity and specificity.

  • Able to perform qualitative analysis with high sensitivity and specificity by using a fluorescent substance

  • Objective result - Eliminates the subjectivity of a visual result

  • Automatic strip recognition by reading the information stored in 2D barcode

  • Time saving by early detection - in case of high titer samples, the analyzer automatically show the test results in 5 minutes.

STANDARD F Dengue IgM/IgG FIA

STANDARD F Dengue IgM/IgG FIA qualitatively analyzes Dengue virus specific IgM and IgG antibodies in serum, plasma and whole blood using fluorescent immunoassay. Screening test results can be obtained within 15 minutes with high sensitivity and specificity.

  • Able to perform qualitative analysis with high sensitivity and specificity by using a fluorescent substance

  • Objective result - Eliminates the subjectivity of a visual result

  • Automatic strip recognition by reading the information stored in 2D barcode

STANDARD Q Dengue Duo

STANDARD Q Dengue Duo test is an immunochromatographic assay for the detection of NS1 antigen and Dengue virus-specific IgM and IgG antibodies in human serum, plasma, and whole blood. By detecting the NS1 antigen, not only the initial infection can be detected, but also Dengue virus-specific IgM and IgG can be detected at the same time. Screening test results can be obtained within 15 minutes with high sensitivity and specificity.

  • Detect Dengue Ag and Ab simultaneously at once

  • Easy to use, Easy to read and interpret

  • Room temperature storage

STANDARD Q Dengue NS1 Ag

STANDARD Q Dengue NS 1 Ag qualitatively analyzes NS1 antigens specific to Dengu virus in serum, plasma and whole blood using immunochromatography. By detecting Dengue NS1 antigens, the initial infection status of the Dengue virus can be discriminated, and the screening test result can be obtained within 15 minutes with its high sensitivity and specificity.

  • Easy to use, easy to read and interpret

  • Room temperature storage

  • Performance
    Sensitivity : 92.9% (184/198) / Specificity : 98.7% (222/225)

STANDARD Q Dengue IgM/IgG

STANDARD Q Dengue IgM/IgG qualitatively analyzes IgM and IgG antibodies specific to Dengue virus in serum, plasma and whole blood using immunochromatography. By detecting IgM and IgG specific to the Dengue virus, the primary and secondary Dengue virus infections can be discriminated against, and the screening test result can be obtained within 15 minutes with its high sensitivity and specificity.

  • Differential detection of IgG and IgM antibodies

  • Easy to use, easy to read and interpret

  • Room temperature storage

  • Able to read positive/negative infections fast and accurately with a little amount of sample (10 µl)

STANDARD E Dengue NS1 Ag ELISA

STANDARD E Dengue NS1 Ag ELISA analyzes Dengue NS1 antigens in serum and plasma using enzyme-linked immunosorbent assay.

  • Simple and easy to use: All necessary reagents included in the kit

  • Highest accuracy with all dengue serotypes(DEN1,2,3, and 4)

  • Able to detect antigens in samples with high sensitivity and specificity

  • Performance
    Sensitivity : 91.4% (181/198) / Specificity : 98.2% (221/225)

STANDARD E Dengue IgM ELISA

STANDARD E Dengue IgM ELISA analyzes IgM antibodies specific to Dengue virus in serum and plasma using enzyme-linked immunosorbent assay.

  • Simple and easy to use - All necessary reagents included in the kit

  • Highest accuracy with all dengue serotypes(DEN1,2,3, and 4)

  • Performance
    Sensitivity : 97.4% (77/79) / Specificity : 96.6% (346/358)

STANDARD E Dengue IgG ELISA

STANDARD E Dengue IgG ELISA analyzes IgG antibodies specific to Dengue virus in serum and plasma using enzyme-linked immunosorbent assay.

  • Simple and easy to use - All necessary reagents included in the kit

  • Highest accuracy with all dengue serotypes(DEN1,2,3, and 4)

  • Able to detect antibodies in samples with high sensitivity and specificity

  • Performance
    Sensitivity : 97.2% (140/144) / Specificity : 96.2% (282/293)

Malaria

STANDARD Q Malaria/CRP Duo

STANDARD Q Malaria/CRP Duo Test is an immunochromatographic assay for the qualitative detection of P. falciparum specific to HRP-2, Plasmodium species (P. falciparum, vivax, ovale, and malariae) specific to pLDH and C-Reactive Protein (CRP) in human whole blood specimen. For the patient with fever who has Malaria tests negative, CRP test can be used to help differentiate bacterial infection from viral infections. The detection limit of CRP test is 20mg/L. With this results, healthcare provider can provide correct and fast treatment and avoid unnecessarily treating viral infections with antibiotics. This test kit is for in vitro use only. This is intended for professional use, only for an initial screening test.

  • Easy to use, read, and interpret

  • Room temperature storage

STANDARD Q Malaria P.f Ag

STANDARD Q Malaria P.f Ag is a product that qualitatively analyzes Plasmodium falciparum antigens in whole blood using immunochromatography. The target antigen is Histidine-Rich Protein II (HRP-II), and the screening test result can be obtained within 15 minutes with its high sensitivity and specificity.

  • Optimized on-site diagnosis with the small diagnostic kit

  • Room temperature storage

  • Able to read positive/negative infections fast and accurately with a little blood (5µl)

STANDARD Q Malaria P.f/P.v Ag

STANDARD Q Malaria P.f Ag qualitatively analyzes Plasmodium falciparum and Plasmodium vivax antigens in whole blood using immunochromatography. The target antigen is Histidine-Rich Protein II (HRP-II) of Plasmodium faciparum and plasmodium lactate dehydrogenase (pLDH) of Plasmodium vivax, and the screening test result can be obtained within 15 minutes with its high sensitivity and specificity.

  • Distinguish the infection between P.falciparum and P.vivax

  • Optimized on-site diagnosis with the small diagnostic kit

  • Able to read positive/negative infections fast and accurately with a little blood (5µl)

  • Room temperature storage

STANDARD Q Malaria P.f/Pan Ag

STANDARD Q Malaria P.f Ag qualitatively analyzes Plasmodium falciparum and Plasmodium species antigens in whole blood using immunochromatography. The target antigen is Histidine-Rich Protein II (HRP-II) of Plasmodium faciparum and plasmodium lactate dehydrogenase (pLDH) of Plasmadium species, and the screening test result can be obtained within 15 minutes with its high sensitivity and specificity.

  • Distinguish the infection between P.falciparum and others

  • Optimized on-site diagnosis with the small diagnostic kit

  • Able to read positive/negative infections fast and accurately with a little blood (5µl)

  • Room temperature storage

STANDARD E Malaria Ag ELISA

STANDARD E Malaria Ag ELISA analyzes Malaria antigens in whole blood using enzyme-linked immunosorbent assay.

  • Simple and easy to use: All necessary reagents included in the kit

  • Able to detect antigens in samples with high sensitivity and specificity

Chikugunya

STANDARD F Chikungunya IgM/IgG FIA

STANDARD F Chikungunya IgM/IgG FIA qualitatively analyzes Chikungunya virus-specific IgM and IgG antibodies in serum, plasma and whole blood using fluorescent immunoassay. Screening test results can be obtained within 15 minutes with high sensitivity and specificity.

  • Able to perform qualitative analysis with high sensitivity and specificity by using fluorescent substance

  • Objective result - Eliminates the subjectivity of a visual result

  • Automatic strip recognition by reading the information stored in the 2D barcode

STANDARD Q Chikungunya IgM/IgG

STANDARD Q Chikungunya IgM/IgG qualitatively analyzes IgM and IgG antibodies specific to Chikungunya virus in serum, plasma and whole blood using immunochromatography. Screening test results can be obtained within 15 minutes with high sensitivity and specificity.

  • Differential detection of IgG and IgM antibodies

  • Easy to use, easy to read and interpret

  • Room temperature storage

  • Able to read positive/negative infections fast and accurately with a little amount of sample (10 µl)

STANDARD E Chikungunya IgG ELISA

STANDARD E Chikungunya IgG ELISA analyzes IgG antibodies specific to Chikungunya virus in serum and plasma using enzyme-linked immunosorbent assay.

  • Simple and easy to use - All necessary reagents included in the kit

STANDARD E Chikungunya IgM ELISA

STANDARD E Chikungunya IgM ELISA analyzes IgM antibodies specific to Chikungunya virus in serum and plasma using enzyme-linked immunosorbent assay.

  • Simple and easy to use - All necessary reagents included in the kit

Yellow fever

STANDARD Q Yellow Fever IgM

STANDARD Q Yellow Fever IgM Test qualitatively analyzes IgM antibodies specific to Yellow Fever virus in serum, plasma, and whole blood using immunochromatography. Screening test results can be obtained within 15 minutes with high sensitivity and specificity.

  • Differential detection of IgM antibodies

  • Easy to use, Easy to read and interpret

  • Room temperature storage

  • Able to read positive/negative infections fast and accurately with a little amount of sample (10 µl)

Leptospira

STANDARD Q Leptospira IgM/IgG

STANDARD Q Leptospira IgM/IgG qualitatively analyzes IgM and IgG antibodies specific to Leptospira interrogans in serum, plasma, and whole blood using immunochromatography. Screening test results can be obtained within 15 minutes with high sensitivity and specificity.

  • Differential detection of IgG and IgM antibodies

  • Easy to use, Easy to read and interpret

  • Room temperature storage

  • Able to read positive/negative infections fast and accurately with a little amount of sample (10 µl)

Tsutsugamushi

STANDARD F Tsutsugamushi IgM/IgG FIA

Scrub typhus is a disease caused by Orientia tsutsugamushi that is spread through chiggers (larval mites). STANDARD F Tsutsugamushi IgM/IgG FIA is a fluorescent immunoassay for the detection of O. tsutsugamushi bacteria-specific IgM and IgG antibodies in human whole blood, serum, and plasma samples.

  • Able to perform qualitative analysis with high sensitivity and specificity by using a fluorescent substance

  • Automatic strip recognition by reading the information stored in the 2D barcode

  • Objective result - Eliminates the subjectivity of a visual result

  • Reagents can be stored at room temperature : : 2-30℃ / 36-86℉

STANDARD Q Tsutsugamushi IgM/IgG

STANDARD Q Tsutsugamushi IgM/IgG qualitatively analyzes IgM and IgG antibodies specific to Orienta tsutsugamushi in serum, plasma, and whole blood using immunochromatography. Screening test results can be obtained within 15 minutes with high sensitivity and specificity.

  • Differential detection of IgG and IgM antibodies

  • Easy to use, Easy to read and interpret

  • Room temperature storage

  • Able to read positive/negative infections fast and accurately with a little amount of sample (10 µl)

Lyme

STANDARD F Lyme IgM/IgG FIA

Lyme disease is caused by the bacteria, Borrelia burgdorferi that is transmitted through black-legged or deer tick. STANDARD F Lyme IgM/IgG FIA is a fluorescent immunoassay for the detection of B. burgdorferi specific IgM and IgG antibodies in human whole blood, serum, and plasma samples.

  • Able to perform qualitative analysis with high sensitivity and specificity by using fluorescent substance

  • Objective result - Eliminates the subjectivity of a visual result

  • Automatic strip recognition by reading the information stored in 2D barcode

  • Reagents can be stored at room temperature : : 2-30℃ / 36-86℉

bottom of page